Communication Protocol for Baracoda ScanWear/ToughRunners Scanners
Sept. 07 5/26
0xD? Communication commands
0xD5 Get Radio behavior when in charge
0xD6 Set Radio behavior when in charge
0xE? RESERVED
0xF? Power saving commands
0xF0 Get shutdown timers
0xF1 Set shutdown timers
0xF2 Get battery status
3/ Command details
3.1/ Setting mode
Command ID 0x01
Description Enter Setting mode
Length 0
payload none
Response 0 (1 = ERROR)
Command ID 0x02
Description Exit Setting mode
Length 0
payload none
Response 0 (1 = ERROR)
A radio disconnection leads to an exit from this setting mode.
3.2/ Operational statistics
Command ID 0x05
Description Retrieve operational statistics
Length 0
payload none
Response 10 bytes : AAAABBBBCC
where :
AAAA = Number of scans done
BBBB = Operating time (minutes)
CC = Number of charge cycles done (MSB first)
Command ID 0x06
Description Reset operational statistics
Length 10
payload 10 bytes : AAAABBBBCC
where :
AAAA = Number of scans done
BBBB = Operating time (minutes)
CC = Number of charge cycles done (MSB first)
Response 0 (1 = ERROR)